1430562 Potter E2 D1xB2X05 Explosion Proof Xenon Strobe Beacon 5 Joules 12-24VDC - Red Enclosure - Clear Lens
MSRP:
$2,492.00
$2,056.00
(You save
$436.00
)
- Brand
- Potter
- SKU:
- 1430562
Features:
- Model Number - D1XB2X05DC024MN1A1C
- Item Number - 1430562
- Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
- Automatic synchronisation on multi-beacon system
- A4 316 Stainless Steel guard included as standard
- UV stable polycarbonate lens colour filter field replaceable
- 4 x side, 1 x pendant cable entries stopping plugs included
- Corrosion proof marine grade aluminium enclosure
- UL 1638 & CAN/ULC S526 signaling device for Fire Alarm
Approved to UL1638 and CAN/ULC S526 for fire alarm use the D1xB2X05 beacons produce a high output Xenon flash required for effective signalling in environments with elevated levels of ambient light. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC. The robust enclosure features a threaded flame path, four cable entries. Mounting options include surface via integrated lugs, pendant or by addition of optional multi direction stainless steel bracket. SIL1 compliant to IEC61508 (2010) as standard SIL2 version available.
Specifications
- Source - Xenon Strobe
- Energy - 5 Joules (5Ws)
- Flash rates
- 1Hz flash (60 fpm)
- 1.3Hz flash (80 fpm)
- 1.5Hz flash (90 fpm)
- Double flash (120 fpm)
- Eff. Intensity cd - 20.44cd UL1638 Private mode fire
- Eff. Intensity cd - 156.65cd measured ref to I.E.S
- Eff. Intensity cd - 250 cd calculated from energy (J)
- Peak Candela - 500,000 cd calculated from energy (J)
- Lens colours - Amber, Blue, Clear, Green, Magenta, Red & Yellow
- Voltage DC - 24V dc (20-28Vdc)
- In-rush - 828mA within 6ms @ 24Vdc
- Ingress protection - IP rating per EN60529:IP66/67, Type rating per UL50E/NEMA250:4/4X/3R/13
- Lens material - High impact Borosilicate glass
- Enclosure material - Marine grade LM6 aluminium alloy
- Enclosure colour - Red or Grey, custom colours available on request
- Enclosure finish - Chromate & powder coated finish
- Cable entries
- Side - 2 × 3/4"NPT & 2 x M20x1.5mm
- Pendant - 1 × 3/4"NPT, Stopping plugs included
- Stopping plugs - Brass, Nickel Plated or Stainless Steel
- Terminals - 0.5 2.5mm² (20-14 AWG), Duplicated terminals
- Line monitoring - Blocking diode included, EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
- Ground/Earth stud - M5
- Enclosure volume - <2 litres
- Installation temp - -55 to +80°C [-67° to +176°F]
- Storage temp - -55 to +80°C [-67° to +176°F]
- Relative humidity - 95% Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
- MTBF DC - 198.88 years / 1,742,161 hours MIL 217
- MTBF AC - 253.68 years / 2,222,223 hours MIL 217
- Weight - 3.2kg/7.1Ibs